- Lab water system
- Medical water system
- Industrial water system
|
|
With 7.0 inch touch screen system, 3 way water quality sensor, 2 way flow sensor for quantified dispensing, 2 stage RO system and EDI module, Center-EDI series deionized water system is top choice of high flux deionized water for general grade experiments.
With tap water inlet, its output ranges from 45 to 90 liters/hour. It can produce 2nd stage RO water and deionized water. The 2nd stage RO water´s conductivity can stay 1-5&Micro;s/cm, and the deionized water´s resistivity absolutely reaches to 10MΩ.cm. It completely meets the requirements of general chemical or biological experiments for pure water.
|
Flow Schematic
Specifications
| Model |
Center-EDI 45D |
Center-EDI 60D |
Center-EDI 90D |
| Output -EDI water* |
45 liters/hour |
60 liters/hour |
90 liters/hour |
| EDI water quality |
 |
| Resistivity |
>10MΩ.cm |
| TOC* |
<30ppb |
| Silicone rejection rate |
>99.9% |
| Bacteria |
<0.01cfu/ml |
| Particle(>0.2&Micro;m) |
<1/ml |
| RO water quality |
 |
| Conductivity - 1st stage RO water |
Feed water conductivity×5%* |
| Conductivity - 2nd stage RO water |
1-5&Micro;s/cm* |
| Feed water requirements |
Tap water, temperature:5-45°C,pressure:1.0-4.0Kgf/cm2 |
| Dimension and weight |
Length × Width × Height: 610×585×1580mm / Weight: about 70Kg |
| Electrical requirements |
AC110-240V, 50/60Hz |
| Power |
480W |
| Standard configuration |
Main body (Including 1 set of cartridge)+built-in 20 liters PE tank and 20 liters pressure tank |
Remarks:
*The value will be influenced by temperature and feed water´s quality.
Cartridges |
| Item no. |
Commodity |
Approximate replacement term /set |
| C-PP |
Pretreatment cartridge |
2-6 months |
| C-AK |
KDF+ granular active carbon mixed cartridge |
12 months |
| C-AC2 |
Active carbon block cartridge |
6 months |
| C-RO-200 |
200 GPD reverse osmosis membrane |
12-24 months |
| C-RO-300 |
300 GPD reverse osmosis membrane |
12-24 months |
| C-RO-400 |
400 GPD reverse osmosis membrane |
12-24 months |
| C-RO-500 |
500 GPD reverse osmosis membrane |
12-24 months |
| C-RO-600 |
600 GPD reverse osmosis membrane |
12-24 months |
| C-EDI-HX50 |
EDI module |
12-36 months |
| C-EDI-HX100 |
EDI module |
12-36 months |
| C-Decart1 |
High flux mixed bed resin cartridge |
35000 liters pure water |
| C-Pocart3 |
High flux ultrapure polishing resin cartridge |
35000 liters pure water |
| C-Pocart4 |
Ultrapure polishing resin cartridge |
5000 liters pure water |
| C-Uvlcart-14W |
(254&185)nm wavelength uv module |
-- |
| C-Uvlamp-14W |
(254&185)nm wavelength uv lamp |
9000 hours |
| C-Ufcart |
Eliminating endotoxin uf cartridge |
-- |
| C-Tefit |
0.2µm terminal filter |
-- |
|