- Lab water system
- Medical water system
- Industrial water system
|
|
With LCD controlling system, 3 way water quality sensor, cartridge replacing alarm, timing and quality dispensing, stainless steel shell, built-in 2 set pressure tanks, single stage RO system and 1 pump, Medium-Q series deionized water system is superior choice of deionized water’s mass usage for general grade experiments.
With tap water inlet, its output ranges from 45 to 125 liters/hour. It can produce single stage RO water and deionized water. The single stage RO water’s ion rejection rate is more than 97%, and the deionized water’s resistivity is more than 10MΩ.cm, near to18.2MΩ.cm. It completely meets the requirements of general chemical or biological experiments for pure water.
|
Flow Schematic

Specifications
| Model |
Medium-Q300 |
Medium-Q400 |
Medium-Q600 |
Medium-Q800 |
| Output(25°C)* |
45 liters/hour |
63 liters/hour |
94 liters/hour |
125 liters/hour |
| Pure water outlet |
2: reverse osmosis water, deionized water |
| Deionized water quality |
 |
 |
 |
 |
| Resistivity |
10-18.2MΩ.cm |
| Bacteria |
<0.01cfu/ml |
| Particle(>0.2µm) |
<1/ml |
| RO water quality |
 |
 |
 |
 |
| Ion rejection rate |
97%-99% (new RO membrane) |
| Organic rejection rate |
>99%, when MW>200 Dalton |
| Particles and bacteria rejection rate |
>99% |
| Feed water requirements |
Tap water, temperature:5-45°C,pressure:1.0-4.0Kgf/cm2 |
| Dimension and weight |
Length×Width×Height:640×540×1110mm / Weight: about 65Kg |
| Electrical requirements |
AC110-240V, 50/60Hz |
| Power |
120W |
240W |
| Standard configuration |
Main body (Including 1 set of cartridge)+2 set built-in 15 liters pressure tank |
Remarks:
*The value will be influenced by temperature and feed water’s quality.
Cartridges |
| Item no. |
Commodity |
Approximate replacement term /set |
| PC-20PP |
20" spun fiber cartridge |
2-6 months |
| PC-20AC-G |
20" granular active carbon cartridge |
2-6 months |
| PC-20AC-B |
20" active carbon block cartridge |
2-6 months |
| RO-150GPD |
150 GPD reverse osmosis membrane |
12-24 months |
| RO-200GPD |
200 GPD reverse osmosis membrane |
12-24 months |
| RO-300GPD |
300 GPD reverse osmosis membrane |
12-24 months |
| RO-400GPD |
400 GPD reverse osmosis membrane |
12-24 months |
| RO-600GPD |
600 GPD reverse osmosis membrane |
12-24 months |
| PTC-AC-HZB1 |
Reducing TOC cartridge |
9000 liters pure water |
| PTC-MBR-12L |
12l mixed bed resin cartridge |
20000 liters pure water |
| PTC-UPPR-12L |
12l ultrapure polishing resin cartridge |
20000 liters pure water |
| PTC-MBR-25L |
25l mixed bed resin cartridge |
40000 liters pure water |
| PTC-UPPR-25L |
25l ultrapure polishing resin cartridge |
40000 liters pure water |
| PTC-UPPR-M |
Ultrapure polishing resin cartridge |
1000 liters pure water/set |
| TF-0.2µm-B |
0.2µm terminal filter |
- |
| UF-5000D |
MWCO5000D UF cartridge |
- |
| LAMP-(185nm&254nm)-10W-M |
Double wavelength(185&254)nm uv lamp |
9000 hours |
|